ELTROPULS - Bell annealing furnace Stock-No. 03402
Offer details
Stock-No.
03402
Type of machine
Bell annealing furnace
Make
ELTROPULS
Type
DG 320/250
Year of manufacture
2008
Type of control
konventionell
Technical details
Dimensions (L/W/H)
13,25 x 5.50 x 8.40 m
0
max. 333 m³/min
total power requirement
max. 350 kW
- ca. 324
additional information
- Exhaust air:
- - Volume flow during cooling: max. 333 m³ / min Hood
- - Air outlet temperature: max. 350°C with fan run typ. 80°C
-
- Cooling water:
- - Inlet: p = 4 - 5 bar, 15°C<T < 25°C, V = 8.5 l/min (at ?T = 30 °C)
- - Drain: unpressurized, at floor level
- - Inlet and outlet lines: Hot air hose SCA 110 10x4.5 (inner Ø 10 mm, wall thickness
- 4.5 mm)
- Exhaust air:
- - Volume flow during cooling: max. 333 m³ / min Hood
- - Air outlet temperature: max. 350°C with fan run typ. 80°C
-
- Cooling water:
- - Inlet: p = 4 - 5 bar, 15°C<T < 25°C, V = 8.5 l/min (at ?T = 30 °C)
- - Drain: unpressurized, at floor level
- - Inlet and outlet lines: Hot air hose SCA 110 10x4.5 (inner Ø 10 mm, wall thickness
- 4.5 mm)
-
- Cooling circuit for the gas/water heat exchanger:
- - Inlet: p = 4 - 5 bar, 15°C < T < 25°C, V = 62.3 l/min (at ?T = 30 °C)
- - Outlet: opens without pressure, outlet height: above cooling tank
- - Inlet: hose DIN 73411 inner Ø 25 mm, wall thickness 3.5 mm
- - Outlet: hose DIN 73411 inner Ø 50 mm, wall thickness 5.0 mm
-
- Compressed air:
- - Connection: DN 10 hose with shut-off valve
- - Pressure range: 6 - 10 bar
-
- Equipment/Accessories:
- - Switch and control cabinet
- - Extraction system
- - technical Documentation
-
-